How to maintain the vacuum pump?
First of all, the user should check the
oil level frequently, and adjust it to meet the requirements if it does not meet
the requirements. When the vacuum pump is running, the oil level shall be up to
the center of the oil mark. Check the oil quality frequently, replace the new
oil in time in case of oil deterioration, and ensure the vacuum pump works
normally. The oil change period shall be considered according to the actual use
conditions and whether it can meet the performance requirements, etc., which
shall be determined by the user at his discretion. General new vacuum pump, when
pumping clean and dry gas, it is recommended to change oil once in about 100
hours. After no ferrous metal powder can be seen in the oil, the oil change
period can be appropriately extended in the future.
Generally, the
vacuum pump shall be overhauled after 2000 hours of operation to check the aging
degree of rubber seal, check whether the exhaust valve plate is cracked, and
clean the dirt deposited on the valve plate and exhaust valve seat. Clean the
parts in the whole vacuum pump, such as rotor, spinner, spring, etc. It is
usually washed with gasoline and dried. Clean rubber parts and dry them with dry
cloth. When cleaning and assembling, handle with care to avoid damage.
If possible, the pipe shall also be cleaned to ensure that the pipeline
is unblocked.
After reassembling the vacuum pump, the test run shall be
carried out. Generally, the vacuum pump shall be idle for 2 hours and the oil
shall be changed for two times. Because there will be a certain amount of
volatile matters left in the vacuum pump during cleaning. After normal
operation, the vacuum pump shall be put into normal operation again, and the
pipeline and joint of the vacuum pump shall be checked for looseness. Turn the
vacuum pump by hand to see if it is flexible. Add bearing lubricating oil into
the bearing, observe that the oil level should be at the center line of the oil
mark, and replace or supplement the lubricating oil in time.
At the
beginning of use, close the gate valve, outlet pressure gauge and inlet vacuum
gauge of the water outlet pipe, jog the motor, and try to see whether the motor
rotation is correct. Start the motor. When the vacuum pump is in normal
operation, open the outlet pressure gauge and the inlet vacuum pump. Gradually
open the gate valve and check the motor load after the appropriate pressure is
displayed. Try to control the flow and head of the vacuum pump within the range
indicated on the label to ensure that the vacuum pump operates at the highest
efficiency point, so as to achieve the maximum energy saving effect. During the
operation of vacuum pump, the bearing temperature shall not exceed the ambient
temperature of 35C, and the maximum temperature shall not exceed 80C. In case of
any abnormal sound of vacuum pump, stop the pump immediately and check the
cause.
To stop using the vacuum pump, first close the gate valve and
pressure gauge, and then stop the motor. In the first month of operation, the
vacuum pump changes the lubricating oil after 100 hours, and then every 500
hours. Adjust the packing gland frequently to ensure that the leakage in the
packing chamber is normal (it is better to leak out in drops). Check the wear
condition of the shaft sleeve regularly, and replace it in time when the wear is
large. When the vacuum pump is used in cold winter, it is necessary to unscrew
the drain plug at the lower part of the pump body to drain the medium after
stopping. Prevent frost cracking. If the vacuum pump is out of service for a
long time, it is necessary to disassemble the pump completely, dry the water,
coat the rotating parts and joints with grease, and properly store them.