Influence of water temperature on water ring vacuum pump
Water ring
vacuum pump is a type of vacuum pump that we can often use. We all know that its
service performance is very good, but it does not rule out accidents. After a
period of use, it is easy to have some unexpected problems. There are many
factors that affect the normal operation of the vacuum pump, so the water
temperature is one of them, whether the water temperature is too high or too
low, it will have a certain impact on the operation of the vacuum pump. So, why
on earth is this? Now let's have a detailed understanding of the reasons.
1. Too high water temperature will make the water evaporate, and the
negative pressure condition will further aggravate the occurrence of this kind
of vaporization and evaporation, making the pump body produce too much water
vapor. In this way, when the water ring vacuum pump inhales too much water
vapor, but seldom inhales outside, resulting in a very low vacuum degree of the
system. There are two main reasons for the high water temperature, one is that
the water supply temperature is too high, the other is that the water
temperature rises in the working process.
2. Because the water
temperature is related to the suction capacity, the working fluid temperature is
high, and the air volume will decrease. With the increase of temperature, the
evaporation capacity increases, occupying the original displacement, and the
suction capacity decreases, which will prolong the vacuumizing time. In
addition, under the vacuum condition, the evaporation capacity of the sealing
liquid will increase with the increase of temperature, and the larger the
percentage of the displacement, the situation that cannot be vacuumized will
occur. As for the data involved too much, the evaporation capacity of sealing
liquid under various vacuum degrees and the evaporation capacity under various
temperatures are not the same, so it is impossible to give specific data. Only
under certain vacuum degrees can the temperature change be reflected and the
evaporation capacity change be caused. In use, it must be combined with
temperature, and the superposition of two performance curves of vacuum degree
and pump performance curve can be seen.
Roots vacuum pump
Liquid Ring
Vacuum compressor
Rotary
Piston Vacuum Pump