How to start the 2be water ring vacuum pump correctly? It needs to be started in a certain order to ensure the normal and stable operation of the equipment, while improving the working efficiency. Here is a detailed introduction:

1. It is preferred to close the high vacuum butterfly valve on the intake pipe.

2. Start the 2be water ring vacuum pump motor.

3. Open the gate valve on the water supply pipeline, the water supply will gradually increase until the water supply meets the requirements.


4. When the pump reaches the limit vacuum, open the gate valve on the intake pipe, and the 2be water ring vacuum pump starts to work normally.

5. It is better to adjust the packing gland to make the water drop. When the vacuum pump is working under the extreme vacuum, the explosion sound will occur due to the physical effect in the pump, but the power consumption will not increase. If the explosion sound is found with the increase of power, it means that the pump has failed. At this time, the pump should be stopped immediately for inspection.

The above is about the introduction of 2be water ring vacuum pump, and incorrect operation sequence may lead to equipment damage. Therefore, before using the 2be water ring vacuum pump, the user must read the operation manual carefully, understand the operation steps and start the equipment to ensure the stability of the equipment.