Correct use of 2SK water ring vacuum pump
Before 2SK water ring vacuum
pump, it is necessary to check whether the rotation direction of the motor is
consistent with that of the pump. After starting the vacuum pump, adjust the
size of the water inlet, and then check whether the packing pressure is
appropriate (normal packing pressure will make the water drop in the pump leak
out). Sk-1.5b should first add water, then start the vacuum pump, and then
adjust the size of the water inlet. The bearing lubrication is normal.
After 2SK water ring vacuum pump is started, it is necessary to observe
whether there is vibration, listen carefully to whether there is noise in SK
cantilever water ring vacuum pump, and measure the temperature of stuffing box
and bearing (the normal bearing temperature shall not be 35 ℃ higher than the
ambient temperature, and the working temperature shall not be higher than 70 ℃).
If the temperature is too high, park the vehicle immediately to check the cause.
When SK cantilever water ring vacuum pump is used as the vacuum water
diversion of the pump, during the operation of the pump, all air in the pump is
sucked out until the water is sucked out to sk cantilever water ring vacuum pump
in the future, that is, start the pump, stop the vacuum pump after the pump
works normally, and seal the suction valve.
Water Ring Vacuum Pump Pipeline Arrangement
Water Ring Vacuum Pump
Water Ring Vacuum Pump manufacturers