Understand the operation of water ring vacuum pump
When using the water
ring vacuum pump, we need to pay attention to water as a very common working
fluid or coolant, which plays an indispensable role in the normal operation of
the water ring vacuum pump and the water ring vacuum degree. Pump can also be
recycled, but only need to pay attention to some details to avoid unnecessary
trouble.
Here, we will especially understand the problem of using the
working fluid of water ring vacuum pump: when the working fluid is recovered, it
can be kept free of impurities. If it is to be recycled, it needs to be used
together with water tank and cooling device. The recommended operating water
temperature is 15-25 ° C. high water temperature will affect the performance of
the pump equipment, such as vacuum degree and pumping capacity.
2BV
water ring vacuum pump generally needs to increase equipment cooling, more
importantly, on-site process and temperature regulation. In fact, most
industries reuse circulating water. If water can be used, it is waste, but
circulation pipeline must be installed. Generally, the working fluid of water
ring vacuum pump shall be industrial soft water.
The water ring vacuum
pump has certain requirements for water temperature and water quality when it
works, mainly to avoid the corrosion of internal impeller and other components,
and whether the vacuum generated is pure. Generally, for the purpose of
recycling water, it can save resources, try to use industrial soft water, so as
to avoid damage to equipment, better achieve the purpose of multiple water use,
achieve the purpose of environmental protection, and save resources.