Safety Operation For Type 2X Rotary Vane Vacuum Pump

2 x type rotary vane vacuum pump to the two-stage structure and its working performance levels by high pressure and low pressure of two parts, its inlet connected to the vacuum container or a vacuum equipment, when operating the gas will be a lot of suction and discharge container. When equipment for vacuum, high pressure stage exhaust valve will be closed, high pressure will be transferred to the second level of inhaled gases, and the secondary suction and discharge, such vacuum equipment can obtain a certain vacuum. The technical parameters of the pump are 6 * 10-2pa. According to user’s usage, can be equipped with a vacuum pump (for example the roots vacuum pump), will be 2 x type rotary vane vacuum pump as the backing pump, due to the suction pneumatic booster pump, pump before continuous pumping, can make you get higher vacuum equipment.safety-operation-for-type-2x-rotary-vane-vacuum-pump


Safety operation and maintenance procedures of rotary vane vacuum pump:

(1) rotary vane vacuum pump should be installed in dry, ventilated and clean places.

(2) in general, rotary vane vacuum pump does not need to be bolted on the foundation, but must be placed smoothly to avoid vibration. For example, the mounting frame, the bolts must be tightened.

(3) connect the power according to the motor sign, install the ground wire and fuse with the appropriate capacity, install the heat relay corresponding to the motor, and rotate the motor in the direction of the arrow shown in the pump.rotary-vacuum-pump-in-medicine