1. Roots Vacuum Pump needs to check the oil level frequently and adjust it to meet the requirements when it does not meet the requirements.
2. The oil change period should be considered according to the actual operating conditions and whether the performance requirements can be met. In general, when pumping clean and dry gas, it is recommended to change oil once in about 100 hours.vacuum-system-in-plasma-spraying
3. Check the oil quality regularly, and replace the new oil in time to ensure its normal operation.
4. After 2000 hours of work, it should be repaired to check the aging degree of the gum seals, check whether the exhaust valve sheet is cracked, and clean up the dirt deposited on the valve sheet and the exhaust valve seat.
5. Clean the parts in the whole Roots vacuum pump chamber, such as rotors, rotary blades, springs, etc., and generally use gasoline to clean and dry them.
6. Add bearing lubricating oil to the bearing body, observe the oil level should be at the center line of the oil mark, and the lubricating oil should be replaced or supplemented in time.
7. Trial operation should be carried out after reassembly. Generally, it should run idly for 2 hours and change oil twice. Because there will be a certain amount of volatile substances in Roots pump when cleaning, and then put into normal operation after normal operation.
All working intensities must be within the range of flow and head of Roots vacuum pump indicated on the label to ensure that it can operate at the most efficient point and achieve the greatest energy-saving effect.Roots_Vacuum_Pump