1. Open the inlet valve of the vacuum pump;rotary-vane-vacuum-pumps
2. Start the vacuum pump and press the operation button (pay attention to observe and judge the operation of the vacuum pump).
liquid ring vacuum pump switching
When switching vacuum pumps, attention should be paid to prevent large fluctuations in vacuum, and the operation instructions should be switched to vacuum pumps. Before starting, check whether the cooling water in the jacket sleeve of the imported pipeline is connected; whether the grounding wire is intact; whether the cooling water of the circulating liquid cooler of vacuum pumps is connected; whether the gas-liquid separator is blown; and whether the inlet valve of vacuum pumps is closed. After the inspection, switch the vacuum pump according to the following steps:liquid-ring-vacuum-pump-china
1. Start the vacuum pump, press the operation button, observe the pressure indication, and then proceed to the next step when the vacuum degree reaches the given value.
2. Open the inlet valve of the vacuum pump slowly, and do the next operation after the vacuum degree indicates stability.
3. Close the inlet valve of the vacuum pump slowly.
4. Stop the operation of the vacuum pump and press the stop button.
5. Stop the cooling water of the circulating liquid cooler of the vacuum pump and close the feed and return valves. The switching of vacuum pump is completed.