Vacuum degree
indicates the thinness of gas in vacuum state. It is usually expressed in terms
of absolute pressure and relative pressure. If the pressure in the measured
equipment is lower than atmospheric pressure, a vacuum gauge is required for
pressure measurement. The value read from the vacuum gauge is called vacuum
degree.
The reason for the vacuum failure of the imported vacuum pump is
not the only one, and our detection method is very single. The whole system has
only one vacuum meter, which can only reflect the final pumping result of the
system, but not the process quantity of each unit at a certain time, which
brings a lot of inconvenience to the troubleshooting and increases the
troubleshooting time.
At present, the troubleshooting method is
basically elimination method, and the steps are as follows:
1. Determine
the accuracy of the vacuum degree instrument of the imported vacuum pump;
2. Ensure that the system shut-off valve is free of leakage;
3.
If the fault is the manifestation of phenomenon I, it is necessary to check the
external leakage of the whole system;
4. If the fault is the
manifestation of phenomenon II, first check whether the parameters of steam,
water and other energy media are abnormal. If not, check each check valve. If
not, conduct system performance test to determine which stage of pump has
performance problems, and check the nozzle and steam valve of the pump.