The structure and principle of the
diffusion pump are evaporator at the bottom and the diffusion pump oil is stored
in it. The upper part is the air inlet, the right side pipe is the air outlet,
and the mechanical pump provides the pre vacuum at the air outlet during
operation. When the oil is heated by the electric furnace, the generated oil
vapor is transmitted along the
The flow tube is ejected downward through
the umbrella nozzle. Because there is vacuum (10-2 ~ 10-3 Torr) provided by
mechanical pump outside the nozzle, the oil steam flow can be ejected for a long
distance and hooked into a jet moving towards the air outlet. When the jet
finally touches the wall cooled by cooling water, it will be given a liquid rest
and flow back to the evaporator for reuse.
Once the gas molecules
entering the pump from the air inlet fall into the steam flow, they will obtain
the downward movement and fly down. Because the jet has high speed (about 200m /
s), high vapor density (several to dozens of Torr of vapor pressure), and the
diffusion pump oil has high molecular weight (350-500), it can effectively take
away gas molecules. Therefore, in the jet interface, gas molecules can not stay
for a long time, and its concentration is very small. In other words, on both
sides of the jet interface, the extracted gas has a large concentration
difference. It is this concentration difference that causes the energy source of
the extracted gas to continuously cross the interface, diffuse into the jet and
be taken to the outlet. There, they are taken away by mechanical pumps.