Today, Xiaobian
introduced to you what should be paid attention to when the stainless steel
vacuum pump is shut down. Let's get to know.
1. First, close the intake
pipe valve and working fluid valve;
2. Stop the motor;
3. Close
the valve in the mechanical seal flushing pipeline;
4. If the ambient
temperature is lower than 0 ℃, discharge the liquid in the pump body, separator
and all pipelines after shutdown;
5. If the stainless steel vacuum pump
is filled with working fluid, it will cause difficulty in starting the stainless
steel vacuum pump. Therefore, after the pump is stopped, it must be ensured that
the liquid cannot enter the pump body and intake pipe from the exhaust pipe,
working liquid supply pipe, etc. If the exhaust side is equipped with a gas
water separator, more attention should be paid. If it is uncertain whether the
pump is filled with working fluid in other installation conditions or in case of
failure, drain the working fluid in the pump before starting or ensure that the
working fluid accounts for about 1 / 2-2 / 3 of the pump cavity.