Disassembly steps of 2BV vacuum pump impeller
The application of 2BV
vacuum pump is more and more extensive. In order to make the equipment use for a
longer time and keep the operation efficiency unchanged, we need to check it in
the use process. When checking 2BV vacuum pump, sometimes we need to dismantle
the impeller, check or replace the blade. Let's learn how to deal with it.
1. There is a screw hole on both sides of the impeller center hole of
2BV vacuum pump. Make a tool. Drill and tap in the middle of a thick iron plate.
The size is smaller than that of the motor shaft. Each end of the hole is milled
with a through slot.
2. After fixing the impeller with two screw holes
on the bolt impeller, use a large bolt to rotate and tighten the motor shaft of
2BV vacuum pump. Rotate this bolt against the motor shaft, and the impeller will
come out slowly. If it is too tight to come out, you can bake the impeller with
fire to make it expand and take out the impeller.
When carrying out
maintenance, we must pay attention to the correct steps to prevent the
imagination that we can't install the parts after they are disassembled. In
addition, some important parts should not be disassembled without authorization.
It is recommended to find a professional to disassemble them.